These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Dynamic bone scanning in fractures. Author: Jacobs RR, Jackson RP, Preston DF, Williamson JA, Gallagher J. Journal: Injury; 1981 May; 12(6):455-9. PubMed ID: 6268541. Abstract: In 20 cases routine static bone scans were no value in the detection of delayed fracture healing. Using the 7.5-15 min net uptake of technetium labelled phosphate, disturbed fracture healing was detected in a series, of 37 cases. Normally healing fractures had an increase of 3 per cent per month and delayed unions less than half that amount. Non-unions had no net uptake.[Abstract] [Full Text] [Related] [New Search]