  • Title: [Extraction of foreign bodies (catheters) from the right atrium and the abdominal aorta by the percutaneous route. Report of 2 cases and review of the literature].
    Author: Espinosa Mejía R, Carrasco Guerra H, Barboza JS, Fuenmayor Arocha A, Phillips V.
    Journal: Arch Inst Cardiol Mex; 1983; 53(2):143-6. PubMed ID: 6349564.
    Abstract:
    Two cases of catheter-fragment embolism from a peripherical vein into the cardiac cavities and their extraction by means of a modified technique are presented. In the first case, the foreign body was located in the right cavities of the heart and it was extracted employing a modified technique by means of a Pigtail catheter and a Bioptom sequentially introduced percutaneously. In the second case, the embolus was located in the abdominal aorta and was extracted percutaneously with a Fogarty catheter. A review of the literature is made and, owing to the increasing frequency of the use of intravascular catheters, some recommendations are made in order to avoid this kind of complications.