These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Column enzyme immunoassay for secretory immunoglobulin A in serum. Author: Yamamoto R, Kimura S, Hattori S, Ishiguro Y, Kato K. Journal: Clin Chem; 1983 Jan; 29(1):151-3. PubMed ID: 6401232. Abstract: This enzyme immunoassay for specific measurement of secretory immunoglobulin A concentrations in human serum involves use of a small chromatographic column as a solid-phase. Serum samples are incubated for 2 h with beta-D-galactosidase-labeled antibody to secretory component, then passed through a 0.1-mL Sepharose 4B column containing antibodies to human immunoglobulin A. After the column is washed to remove the unbound label, the buffer in the column is replaced by a solution of o-nitrophenyl-beta-D-galactoside (a beta-D-galactosidase substrate) and incubated at 25 degrees C overnight. The enzyme reaction is stopped by washing the column with sodium carbonate solution, and the absorbance of the eluate is measured at 420 nm. The concentration of secretory immunoglobulin A can be determined with a minimum detectable sensitivity of 3 mg/L, without interference from free immunoglobulin A and secretory component in the same samples.[Abstract] [Full Text] [Related] [New Search]