These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Stapedectomy revision of the wire-Gelfoam prosthesis. Author: Lippy WL, Schuring AG. Journal: Otolaryngol Head Neck Surg; 1983 Feb; 91(1):9-13. PubMed ID: 6405357. Abstract: Revision procedures in which a vein graft with a Robinson stapes prosthesis was used are reviewed in 100 patients. In all cases a wire-Gelfoam stapes prosthesis had been used initially. The surgical findings were prosthesis malfunction, 48%; eroded incus, 16%; negative findings, 14%; footplate not removed, 11%; oval window fistula, 7%; and incus problems, 4%. Postoperatively, hearing in 70.5% of the patients with conductive hearing loss was within 10 dB and 84.5% within 20 dB. The high success rate is affected by the fact that patients with conductive hearing loss were separated from those with sensorineural hearing loss, a piston prosthesis on tissue was used in the revision surgical procedure, and patients with otosclerosis regrowth did not undergo revision. Surgical directives to minimize hearing loss included use of a tissue seal over the oval window; not reopening the oval window; monitoring the patient for dizziness; performing audiometric tests during surgery; leaving the wire in place in certain cases; and not revising the prosthesis in patients with otosclerosis regrowth.[Abstract] [Full Text] [Related] [New Search]