These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Enzymatic-ultraviolet method for measuring lactose in milk: collaborative study. Author: Kleyn DH, Trout JR. Journal: J Assoc Off Anal Chem; 1984; 67(3):637-40. PubMed ID: 6430867. Abstract: Collaborators in 8 dairy and food industry laboratories performed one lactose determination on each of 8 unknown samples of milk, lowfat milk, or skim milk, as 3 pairs of blind duplicates. Two known samples were provided to gain experience prior to analysis of the unknown samples. All of the above samples were also analyzed for lactose content by the official AOAC gravimetric method (16.507) by a commercial laboratory. From the overall mean of results on all samples, determinations by the enzymatic method averaged 0.49% lower than by the AOAC method. This difference was significant by the t-test (P = 0.05), which indicated a lack of agreement between the compared methods in determining lactose content. Standard deviations were similar for the 3 sets of blind duplicates which ranged between 3.67 and 4.55% lactose content. F-values revealed that variations between means obtained by laboratories differed significantly as compared with variations within laboratory means. The method has been adopted official first action.[Abstract] [Full Text] [Related] [New Search]