These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: In vivo comparison of the nailfold capillary diameter as determined by using the erythrocyte column and FITC-labelled albumin.
    Author: Mahler F, Nagel G, Saner H, Kneubühl F.
    Journal: Int J Microcirc Clin Exp; 1983; 2(2):147-55. PubMed ID: 6432718.
    Abstract:
    The diameter of nailfold capillaries in conventional intravital microscopy is estimated by measuring th width of the erythrocyte-columns. We determined the diameter of the fluorescence-marked microscopy in 33 capillary loops in the nailfold of 12 subjects and compared it with that of the ec-columns. 400-500 mg FITC-albumin were injected into the brachial artery through cannulas inserted for bloodgas analysis. The FITC-marked capillary lumen exceeded the width of the ec-columns of 10.8 +/- 3.0 microns by 4.2 +/- 0.7 microns or by 38% on the arteriolar side, and that of 12.0 +/- 2.7 microns by 4.6 +/- 0.8 microns (p less than 0.01), on the venular side. Venous occlusion produced a significant enlargement of the ec-columns by 13% (p less than 0.01), but no significant increase in the FITC-marked capillary lumen. The difference of 405 microns between the full capillary lumen as represented by the fluorescent plasma space and the width of the ec-columns corresponds presumably to the plasmatic zone between red cells and the vessel wall. No extravasation of FITC-HA was observed neither before nor after venous occlusion.
    [Abstract] [Full Text] [Related] [New Search]