These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Sephadex LH-20 cleanup, high pressure liquid chromatographic assay, and fluorescence detection of zearalenone in animal feeds. Author: Cohen H, Lapointe MR. Journal: J Assoc Off Anal Chem; 1980 May; 63(3):642-6. PubMed ID: 6448837. Abstract: A high pressure liquid chromatographic (HPLC) method is described to determine zearalenone in animal feeds at levels as low as 0.01 ppm. Samples are extracted with chloroform-ethanol and initially purified using a SEP-PAK silica cartridge, followed by column chromatography using Sephadex LH-20. Separation by normal phase HPLC is followed by fluorescence detection. Recoveries at levels of 1.0-0.01 ppm averaged greater than 90%. Confirmation included HPLC analysis of the sample and a zearalenone standard, using 3 different excitation wavelengths, and comparison of fluorescence responses obtained. The method was successfully applied to the analysis of 1 corn and 3 cornmeal samples. Zearalenone was detected in all 4 samples at levels of 0.379-19.2 ppm.[Abstract] [Full Text] [Related] [New Search]