These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: A new formulation of Tc-99m minimicroaggregated albumin for marrow imaging: comparison with other colloids, In-111 and Fe-59. Author: McAfee JG, Subramanian G, Aburano T, Thomas FD, Fernandes P, Gagne G, Lyons B, Zapf-Longo C. Journal: J Nucl Med; 1982 Jan; 23(1):21-8. PubMed ID: 6459431. Abstract: The biodistributions of five Tc-99m colloids were compared with the 24-hr distributions of Fe-59 and In-111 in dogs by direct radioassay 1 hr after intravenous injection. One formulation of Tc-99m minmicroaggregated albumin (particle size 30-100 mn), produced the highest marrow concentration, approximately six times that of Tc-99m sulfur colloid, with similar blood, and liver concentrations and a lower splenic uptake. Nevertheless, the best colloid marrow uptake was lower than the 24-hr value for In-11 and much lower than that for Fe-59. The marrow concentration of minimicroaggregated albumin was also higher than that of sulfur colloid in rats at 30 min after injection. The principal disadvantage of Tc-99m antimony sulfide colloid was its slow blood clearance. Clinical evaluation of Tc-99m minimicroaggregated albumin for marrow imaging appears warranted, although its hepatic activity will obscure overlying and immediately adjacent marrow.[Abstract] [Full Text] [Related] [New Search]