These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Analysis of residues of the fungicide cymoxanil in grapes using multicolumn HPLC].
    Author: Lindner W, Posch W, Lechner W.
    Journal: Z Lebensm Unters Forsch; 1984 Jun; 178(6):471-4. PubMed ID: 6485553.
    Abstract:
    Residues of the contact fungicide Cymoxanil in grapes were determined by a multidimensional multicolumn high pressure liquid chromatography technique (MC-HPLC). The sample pretreatment is a simple water extraction. Further clean-up and trace enrichment of an aliquot of the aqueous acidic sample solution is performed on-line via an automatized microprocessor controlled MC-HPLC system. In the range of 0.05-2.0 mg/kg grapes good linearity is achieved. Recoveries of Cymoxanil added to untreated grapes range between 70% and 80% at 0.05 and 2.0 mg/kg values, respectively, with a reproductibility of s +/- 3% at 0.2 mg/kg (n = 5). The total time for analysis is approximately 30 min.