These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Immune adherence hemagglutination: alternative to complement-fixation serology.
    Author: Lennette ET, Lennette DA.
    Journal: J Clin Microbiol; 1978 Mar; 7(3):282-5. PubMed ID: 649762.
    Abstract:
    Immune adherence hemagglutination (IAHA) was compared to complement fixation (CF), using standard procedures, for serological testing of human sera with a number of commercially available antigens. The antigens included herpes simplex, measles, cytomegalo-, and influenza (type B) viruses, as well as Mycoplasma pneumoniae and Chlamydia psittaci (Chlamydia group). The IAHA test was found to be as specific as the CF test, but 4 to 20 times as sensitive with all antigens tested. Antigen titers were also higher with the IAHA method, and the time required to complete the test was only 4 h for the IAHA method, compared with 20 h for the CF method. The increased sensitivity of the IAHA test should permit its use for determination of immunity, as well as for serodiagnosis of recent infections.
    [Abstract] [Full Text] [Related] [New Search]