These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: A rapid preparative method for isolation of neutral and acidic glycosphingolipids by radial thin-layer chromatography.
    Author: Das KK, Basu M, Basu S.
    Journal: Anal Biochem; 1984 Nov 15; 143(1):125-34. PubMed ID: 6528990.
    Abstract:
    An efficient method to separate neutral and acidic glycosphingolipids (GSLs) from their mixtures within a short period (45-60 min) and with low consumption of solvents (chloroform-methanol-water, 60/35/8 (v/v/v); 250-500 ml) has been developed. This method utilizes a centrifugal thin-layer chromatograph (Chromatotron) and the GSL mixtures (30-400 mg) are applied to glass plates coated with a 1-mm layer of silica gel 60 PF-254. The method (radial thin-layer chromatography) is rapid and simple and the recovery of glycosphingolipids is high (70-80%).
    [Abstract] [Full Text] [Related] [New Search]