These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: A noninvasive determination of fistula blood flow in dialysis patients. Author: Bouthier JD, Levenson JA, Simon AC, Bariety JM, Bourquelot PE, Safar ME. Journal: Artif Organs; 1983 Nov; 7(4):404-9. PubMed ID: 6651579. Abstract: Arteriovenous fistula (AVF) blood flow was evaluated in 32 dialysis patients using a pulsed Doppler velocimeter with two dominant features: a range-gated time system and a double transducer probe. With the proposed apparatus, the observation angle between the ultrasound beam and the vessel axis was known. In radial AVF, blood flow was 728 +/- 53 ml/min and was negatively correlated with the age of the AVF (r = -0.62; p less than 0.01). In brachial AVF, blood flow was 778 +/- 152 ml/min. In bovine heterograft AVF, blood flow was 1,225 +/- 125 ml/min. In the overall population, a negative relationship was observed between the diameter of the fistula and the blood flow velocity (r = -0.57; p less than 0.01). The study describes an accurate noninvasive method for the determination of fistula blood flow in dialysis patients, which may be helpful in the follow-up of the regional hemodynamics of this vascular access.[Abstract] [Full Text] [Related] [New Search]