These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: A simple method for testosterone measurement by high-performance liquid chromatography-UV spectrophotometer.
    Author: Yamada K, Aizawa Y.
    Journal: J Pharmacol Methods; 1983 Nov; 10(3):167-73. PubMed ID: 6656261.
    Abstract:
    A simple, rapid, and reliable method for the separation and quantitation of testosterone in biological samples by a high-performance liquid chromatography-UV spectrophotometer has been developed. Separation of testosterone and prednisolone (I.S.) by HPLC was achieved in less than 3 min on a micro silica gel column using isocratic elution with hexane:chloroform:methanol (3:1:1) as the mobile phase. As little as 5 ng testosterone in biological samples can be estimated accurately by this method. This method seems to provide a new technique for the study of endocrinological pharmacology in animals and human.
    [Abstract] [Full Text] [Related] [New Search]