Search MEDLINE/PubMed


  • Title: Urinary 4-pyridoxic acid excretion in 24-hour versus random urine samples as a measurement of vitamin B6 status in humans.
    Author: Schuster K, Bailey LB, Cerda JJ, Gregory JF.
    Journal: Am J Clin Nutr; 1984 Mar; 39(3):466-70. PubMed ID: 6695847.
    Abstract:
    Urinary excretion of 4-pyridoxic acid (4PA) in 19 men (n = 5) and women (n = 14) was measured to evaluate the validity of determining the 4PA/creatinine ratio in random urine samples as an alternative to total 24-h 4PA excretion in assessing vitamin B6 nutritional status. The relationships among dietary vitamin B6 intake, 4PA excretion, plasma pyridoxal 5'-phosphate levels, and erythrocyte aspartate aminotransferase activity and in vitro stimulation by added plasma pyridoxal 5'-phosphate were examined. The subjects consumed all meals for 3 days in a metabolic unit, and protein intake was kept constant. Plasma pyridoxal 5'-phosphate concentration was positively correlated with vitamin B6 intake of the previous day (r = 0.61, p less than 0.01). There was a positive correlation (r = 0.59, p less than 0.01) between total 4PA and 4PA/creatinine in the 24-h urine samples. No difference (p greater than 0.05) in 4PA/creatinine between the 24-h samples and either morning or afternoon random samples taken the next day was found. These findings support the use of the 4PA/creatinine ratio in random urine samples as an alternative to 24-h urinary 4PA excretion.
    [Abstract] [Full Text] [Related] [New Search]