These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Determination of metoprolol and its alpha-hydroxylated metabolite in human plasma by high-performance liquid chromatography.
    Author: Lecaillon JB, Godbillon J, Abadie F, Gosset G.
    Journal: J Chromatogr; 1984 Feb 10; 305(2):411-7. PubMed ID: 6707168.
    Abstract:
    A high-performance liquid chromatographic method has been developed for the simultaneous determination of metoprolol and its alpha-hydroxylated metabolite in plasma, Metoprolol, alpha-hydroxymetoprolol and alprenolol (internal standard) are extracted from plasma at alkaline pH with diethyl ether-dichloromethane (4:1, v/v) and back-extracted with 0.01 N sulfuric acid. A 100-microliter volume of the acidic extract is injected into the chromatographic system. The compounds are eluted in about 12 min with acetonitrile-acetate buffer (75:25, v/v) on a LiChrosorb RP-8 (5 micron) column. The quantitative determinations are made fluorometrically. Concentrations down to 35 nmol/1 (10 ng/ml) of metoprolol base and 30 nmol/1 (8 ng/ml) of alpha-hydroxymetoprolol base in plasma can be determined with good precision and accuracy.
    [Abstract] [Full Text] [Related] [New Search]