These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Comparison of porcine valve xenografts with mechanical prostheses. A 7 1/2 year experience.
    Author: Joyce LD, Nelson RM.
    Journal: J Thorac Cardiovasc Surg; 1984 Jul; 88(1):102-13. PubMed ID: 6738092.
    Abstract:
    A total of 479 valve replacements were performed in 469 patients for aortic, mitral, and tricuspid disease. A total of 529 valves were implanted (311 Carpentier-Edwards, 118 Hancock, 94 Björk-Shiley, and six other mechanical valves). Of the 479 operations, 51.1% (245) were carried out in male patients and 48.9% (234) were carried out in female patients. The mean age was 57.6 years; however, 28.6% (137) of the operations were performed in patients over 65 years of age. One hundred five patients (21.9%) had had previous cardiac operations of one type or another. Follow-up was 99.6% and the average length of follow-up was 36.2 months. The overall operative mortality was 5.6%. The operative mortality in the isolated aortic valve replacement group was 2.0% and that in the mitral valve replacement group, 4.4%. There was a 5.9% valve explant rate in the Hancock series; however, no valve explants were required because of valve dysfunction in either the Carpentier-Edwards or the Björk-Shiley groups. The thromboembolic rate in the aortic valve position was 2.4, 1.1, and 2.1 emboli per 100 patient-years in the Hancock, Carpentier-Edwards, and Björk-Shiley groups, respectively. The thromboembolic rate in the mitral valve position was 2.8, 2.2, and 1.0 emboli per 100 patient-years in the Hancock, Carpentier-Edwards, and Björk-Shiley groups, respectively.
    [Abstract] [Full Text] [Related] [New Search]