  • Title: Radiant energy and insensible water loss in the premature newborn infant nursed under a radiant warmer.
    Author: Baumgart S.
    Journal: Clin Perinatol; 1982 Oct; 9(3):483-503. PubMed ID: 6761034.
    Abstract:
    Radiant warmers are a powerful and efficient source of heat serving to warm the cold-stressed infant acutely and to provide uninterrupted maintenance of body temperature despite a multiplicity of nursing, medical, and surgical procedures required to care for the critically ill premature newborn in today's intensive care nursery. A recognized side-effect of radiant warmer beds is the now well-documented increase in insensible water loss through evaporation from an infant's skin. Particularly the very-low-birth-weight, severely premature, and critically ill neonate is subject to this increase in evaporative water loss. The clinician caring for the infant is faced with the difficult problem of fluid and electrolyte balance, which requires vigilant monitoring of all parameters of fluid homeostasis. Compounding these difficulties, other portions of the electromagnetic spectrum (for example, phototherapy) may affect an infant's fluid metabolism by mechanisms that are not well understood. The role of plastic heat shielding in reducing large insensible losses in infants nursed on radiant warmer beds is currently under intense investigation. Apparently, convective air currents and not radiant heat energy may be the cause of the observed increase in insensible water loss in the intensive care nursery. A thin plastic blanket may be effective in reducing evaporative water loss by diminishing an infant's exposure to convective air currents while being nursed on an open radiant warmer bed. A rigid plastic body hood, although effective as a radiant heat shield, is not as effective in preventing exposure to convection in the intensive care nursery and, therefore, is not as effective as the thin plastic blanket in reducing insensible water loss. Care should be exercised in determining the effect of heat shielding on all parameters of heat exchange (convection, evaporation, and radiation) before application is made to the critically ill premature infant nursed on an open radiant warmer bed.
    [Abstract] [Full Text] [Related] [New Search]