  • Title: The need for a sufficient number of low level sera in comparisons of different serum vitamin B12 assays.
    Author: Gijzen AH, de Kock HW, Meulendijk PN, Schmidt NA, Schopman W, Tertoolen JF, Voogd CE.
    Journal: Clin Chim Acta; 1983 Jan 24; 127(2):185-95. PubMed ID: 6825315.
    Abstract:
    Eight radiochemical methods for the assay of vitamin B12 in serum were compared with the microbiological assay with Lactobacillus leichmannii ATCC 7830 using 198 individual sera of patients. There was a good agreement between the results of most samples with some kits and the microbiological assay. However, especially in the sera of vitamin B12-deficient patients large discrepancies between the results could occur. These variations were due to both the kits used and the performance of the assays in different laboratories. A sufficient number of non-pooled sera of vitamin B12-deficient patients should be included in investigations to validate radiochemical methods.