These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Histology and fertility after microsurgical anastomosis of the rabbit fallopian tube with nylon and polyglactin sutures. Author: Sojo D, Pardo JD, Nistal M. Journal: Fertil Steril; 1983 May; 39(5):707-11. PubMed ID: 6840311. Abstract: Polyglactin and nylon suture material were compared in microsurgical anastomosis of oviduct of rabbits with regard to the histologic reaction, adhesion formation, and nidation index. Thirty days after surgery, the tissue inflammatory response was very similar in both groups. At 90 days, polyglactin had been totally absorbed in 80% of the cases, and no inflammatory reaction persisted at the site of the suture. At this time, multinucleated giant cell reaction to nylon sutures was persistent but minimal. The results reveal no significant functional differences between oviduct reanastomosed with nylon versus polyglactin suture. No significant difference in subsequent fertility due to suture selection was demonstrated.[Abstract] [Full Text] [Related] [New Search]