These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Continuous haemofiltration maintains fluid balance and reduces haemodialysis requirement in acute renal failure. Author: Dodd NJ, Turney JH, Parsons V, Weston MJ. Journal: Proc Eur Dial Transplant Assoc; 1983; 19():329-33. PubMed ID: 6878249. Abstract: We have used continuous arteriovenous haemofiltration with Amicon 20S Diafilters in combination with conventional haemodialysis as routine management for acute oliguric renal failure in fifteen patients. Haemofiltration provided a variable fluid output of up to eight litres daily, enabling unrestricted nutrition and reduced frequency of haemodialysis.[Abstract] [Full Text] [Related] [New Search]