These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: An enzyme immunoassay for plasma betamethasone.
    Author: Kominami G, Yamauchi A, Ishihara S, Kono M.
    Journal: Steroids; 1981 Mar; 31(3):303-14. PubMed ID: 7014462.
    Abstract:
    A sensitive enzyme immunoassay for plasma betamethasone was developed using betamethasone-3-(O-carboxymethyl)oxime-beta-D-galactosidase conjugate as a labelled antigen and 4-methylumbelliferyl-beta-D-galactoside as a fluorescence substrate. The performances of the enzyme immunoassay were compared with that of a radioimmunoassay using 3H-betamethasone and the same antiserum. The minimal detectable level for the enzyme immunoassay was 0.15 pg/tube or 0.15 ng/ml of plasma, which was remarkably more sensitive than the radioimmunoassay level of 10 pg/tube or 2 ng/ml of plasma. The specificity was sufficient, in particular, the cross reactivity of cortisol as 0.008%. However, the precision of the enzyme immunoassay was inferior to that of the radioimmunoassay.