    Abstract:
    Quantitative indices are described for assessing the distribution of ventilation imaging agents (radioaerosols, in particular) within the lung. They have been applied to images obtained with 99Tcm aerosol particles (0.5-2.0 micrometer diameter) and with 81Krm gas in 12 patients with a wide range of lung function. In patients with normal lung function aerosol distribution was similar to that of 81Krm. In patients with airways obstruction, the aerosol tended to penetrate less well than 81Krm to the lung periphery and to show a less homogeneous distribution there. Quantitative analysis confirms that the aerosol technique is an effective substitute for 81Krm in patients with normal lung function. When lung function is impaired aerosol images may still be valuable particularly in confirming a diagnosis of pulmonary embolism though they must be interpreted with caution in attempting to exclude that diagnosis. We conclude that small particle radioactive aerosols provide a readily available ventilation technique for clinical ventilation-perfusion imaging.