These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Treatment of intertrochanteric fracture of the femur using sliding screw plate fixation. Author: Wolfgang GL, Bryant MH, O'Neill JP. Journal: Clin Orthop Relat Res; 1982 Mar; (163):148-58. PubMed ID: 7067245. Abstract: Sliding screw plate fixation of intertrochanteric fractures of the femur is not always a simple operation with universally excellent results. There is a need to recognize potential pitfalls of this technique by careful analysis of a large number of cases. A retrospective study of 295 intertrochanteric fractures of the femur over a nine-year period was conducted. All fractures were fixed with a sliding screw sideplate device. Mechanical fracture complications occurred in 9% of 142 stable fractures and 19% of 37 unstable fractures. Medial displacement fixation reduction lowered the complication rate of unstable fractures to 10% of 19 cases. A roentgenographic study of 179 hips identified a technical error rate of 22.9% using described criteria. Including 39 deaths, 30 fracture complications, and 45 general complications, the serious complication rate was 38.6%. The sliding screw sideplate device can provide satisfactory fixation, but success is dependent on many other factors, including reduction, operative technique and postoperative care.[Abstract] [Full Text] [Related] [New Search]