These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: A xenon ionization detector for digital radiography.
    Author: Drost DJ, Fenster A.
    Journal: Med Phys; 1982; 9(2):224-30. PubMed ID: 7087908.
    Abstract:
    Xenon gas x-ray detectors have been used successfully in CT scanners; however, they have been found to be unsuitable for digital radiography. We have designed and built a new type of xenon x-ray detector array and tested its suitability for digital radiography. The detector consists of two parallel plates separated by a 0.5-mm gap, filled with xenon gas at a pressure of about 30 atm. One of the plates is the high-voltage electrode, while the other is a circuit board etched to form an array of metal collector strips focused on the x-ray source. Since there are no metal septa separating the individual detector elements, the dose efficiency of the detector is high, but image degradation will occur due to cross-talk between detector elements. Measurements of the cross-talk show that about an 18% reduction in contrast will occur, when a low contrast object, subtending one detector element, is imaged. We have also measured a detector MTF of 14% at 2 lp/mm, a signal of 10 pC for a 1-mR x-ray exposure at the detector entrance, a 6% nonlinearity in the detector signal over about 3 orders of magnitude in x-ray exposure, and a charge collection time (time response) of about 0.1 ms. From these results it is concluded that this new detector design is feasible for digital radiography.
    [Abstract] [Full Text] [Related] [New Search]