These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: A non-competitive solid-phase radioimmunoassay for human aldolase A.
    Author: Asaka M, Nagase K, Miyazaki T, Alpert E.
    Journal: Clin Chim Acta; 1982 Oct 13; 125(1):31-40. PubMed ID: 7139946.
    Abstract:
    A solid-phase, non-competitive radioimmunoassay for aldolase A in human serum has been developed. Human aldolase A was purified from muscle, and specific antisera to the purified aldolase A were obtained from chickens. Specific IgG anti-human aldolase A was purified by affinity chromatography. Disposable polypropylene plates were coated with specific IgG antibody and used for radioimmunoassay with 125I-specific IgG antibody to aldolase A. The non-specific binding was minimized by saturating the binding sites of the plates with 2% ovalbumin in 0.1% Tween 20. This radioimmunoassay is specific for the aldolase A subunit, with no cross-reactivity with human aldolase B subunit or homopolymeric human aldolase C(C4). The serum aldolase A immunoreactivities of 33 normal subjects ranged from 124 to 212 ng/ml with a mean of 178 +/- 41 ng/ml (+/- 2 SD). Ninety-three patients' sera were assayed with both a solid-phase non-competitive radioimmunoassay and a competitive double antibody radioimmunoassay developed in our laboratory and the results showed a high degree of correlation (r = 0.912; p less than 0.001). Rapidity and simplicity of the solid-phase assay makes it superior to other methods for the measurement of serum aldolase isozymes.
    [Abstract] [Full Text] [Related] [New Search]