These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Energy dependence of etch pit diameter in a CR-39 detector for alpha-particles with the energy from 1.29 to 5.48 MeV. Author: Ishigure N, Matsuoka O. Journal: Radioisotopes; 1982 Sep; 31(9):447-52. PubMed ID: 7156417. Abstract: The characteristics for alpha-particle recording of CR-39 plastics was studied for practical use. Sample detectors were irradiated with alpha-particles at normal incident angle. The energy was varied from 1.29 to 5.48 MeV. Tracks of alpha-particles could sufficiently be recognized through the etch pit observation with 1 hour etching in 30% solution of NaOH at a temperature of 70 degrees C. The etch pit diameter decreased almost linearly with the energy of alpha-particles at the early stage of etching, which suggested the possibility of the estimation of alpha-particle energy. The energy resolution was evaluated from the FWHM of the measured distribution of etch pit diameters and found to be about 1.8 MeV for 1, 2 and 3 hour etching.[Abstract] [Full Text] [Related] [New Search]