These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Determination of low concentrations of carbon monoxide in the air by gas chromatography].
    Author: Palus J, Majka J, Sokal J.
    Journal: Med Pr; 1982; 33(5-6):283-8. PubMed ID: 7182709.
    Abstract:
    Determination of carbon monoxide by gas chromatography was described. Having been separated from other air components, carbon monoxide is reduced to methane in the presence of nickel catalyst and determined on the flame-ionization detector. A rectilinear dependence was found between the peak surface or height and CO concentration within 0,5-1000 ppm. The low detectability limit was 0.2 ppm.
    [Abstract] [Full Text] [Related] [New Search]