These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Aberrant position of a central venous catheter: a cause for inadequate fluid replacement in septic shock.
    Author: Krausz MM, Berlatzky J, Eimerl D, Cotev S.
    Journal: Crit Care Med; 1978; 6(5):337-8. PubMed ID: 720091.
    Abstract:
    An unusual placement of a "central" venous catheter in the porto-hemiazygous system of a cirrhotic patient in septic shock is described. The catheter was misinterpreted as being located in a central vein and served initially as a guide for volume replacement. The high central venous pressure recorded (22 cm H2O) in spite of signs of hypovolemia led to the introduction of a Swan-Ganz catheter which confirmed the presence of hypovolemia. The proper position of the central venous catheter, especially in cirrhotic patients, should not only be confirmed by plain chest x-ray but also by injection of contrast medium.
    [Abstract] [Full Text] [Related] [New Search]