These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Complications of anterior resection of the rectum using the EEA stapling device.
    Author: Cade D, Gallagher P, Schofield PF, Turner L.
    Journal: Br J Surg; 1981 May; 68(5):339-40. PubMed ID: 7225760.
    Abstract:
    Fifty patients had anterior resection of the rectum performed with end-to-end anastomosis using the EEA stapling device. The instrument certainly facilitated low anastomoses, but anastomotic dehiscence occurred in 3 cases, stenosis in 2, wound sepsis in 10, some degree os incontinence (usually only temporary) in 7 and anal fissure in 4 cases.
    [Abstract] [Full Text] [Related] [New Search]