These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Contrasts between intrathoracic pressures during external chest compression and cardiac massage. Author: Chandra N, Guerci A, Weisfeldt ML, Tsitlik J, Lepor N. Journal: Crit Care Med; 1981 Nov; 9(11):789-92. PubMed ID: 7297083. Abstract: Pressures were measured in the right atrium, thoracic aorta, and pleural space during conventional cardiopulmonary resuscitation (CPR) and simultaneous ventilation compression cardiopulmonary resuscitation (SVC-CPR) in dogs, pigs, and a baboon. During both forms of closed chest resuscitation, the changes in atrial and aortic pressures were virtually identical over a range of 0-90 mm Hg and essentially equaled the change in pleural pressure measured at the most lateral portion of the chest cavity. During internal cardiac massage, there was no consistent relationship between right atrial and aortic pressures. However, even after the chest had been opened, the hemodynamics of external chest compression could be restored by the creation of a closed, air filled cavity surrounding the heart and great vessels. Thus, elevation of intrathoracic pressure, not direct cardiac compression, is essential to and determine circulation of blood during CPR.[Abstract] [Full Text] [Related] [New Search]