These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Negative intraventricular diastolic pressure in patients with mitral stenosis: evidence of left ventricular diastolic suction.
    Author: Sabbah HN, Anbe DT, Stein PD.
    Journal: Am J Cardiol; 1980 Mar; 45(3):562-66. PubMed ID: 7355753.
    Abstract:
    Left ventricular diastolic pressure was evaluated in 15 patients with mitral stenosis and 16 patients with no significant heart disease to determine if a stenotic mitral valve can cause the left ventricle to produce a negative diastolic pressure, indicative of ventricular diastolic suction. The minimal level of diastolic pressure in patients with mitral stenosis ranged between 6 and -7 mm Hg; in normal subjects it did not fall below 0. The average value of minimal diastolic pressure in patients with mitral stenosis (-2 +/- 1 mm Hg [mean +/- standard error of the mean]) was significantly lower than in patients without significant heart disease (5 +/- 1 mm Hg) (p less than 0.001). These observations indicate that the human left ventricle, in the presence of mitral stenosis, can generate a negative diastolic pressure. The presence of a negative diastolic pressure in patients with mitral stenosis suggests that the dynamics of the ventricle during diastole may contribute to the filling process.
    [Abstract] [Full Text] [Related] [New Search]