These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Late results of replacement of cardiac valves by dura-mater allografts.
    Author: Stolf NA, Puig LB, Zerbini EJ.
    Journal: Int J Artif Organs; 1980 Mar; 3(2):104-7. PubMed ID: 7364504.
    Abstract:
    Homologous dura-mater valve was employed in a series of 2.338 patients in the period between January 1971 and January 1979. A restricted group of the first 272 patients were followed-up from six to eight years. This study showed gratifying results following mitral and tricuspid valves replacement and not as satisfactory results after aortic replacement. The postoperative complications were, for mitral valve: fungal endocarditis (0.68%), bacterial endocarditis (2.56%) thromboembolism (1.36%) valve dysfunction (12.9%) and reoperation was performed in 5.12% of the cases. For aortic valve replacement there was fungal endocarditis in 1.36% of cases, bacterial endocarditis in 5.68%, valve dysfunction in 29.54% and the incidence of reoperation was 23.28%. No anticoagulants were employed in this series.
    [Abstract] [Full Text] [Related] [New Search]