These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Review of the 4-hexylresorcinol procedure for acrolein analysis.
    Author: Hemenway DR, Costanza MC, MacAskill SM.
    Journal: Am Ind Hyg Assoc J; 1980 Apr; 41(4):305-8. PubMed ID: 7395750.
    Abstract:
    The purpose of this paper is to present laboratory results showing major problems with the 4-hexylresorcinol method used for acrolein analysis. A discrepancy in the analytical procedure described by ASTM and NIOSH gives rise to underestimation of acrolein levels based on the length of time the mixed reagents have been prepared prior to sampling. Underestimations by as much as 35% may occur due to the problems in the existing methodologies.
    [Abstract] [Full Text] [Related] [New Search]