Title: Analysis of isoxazolyl penicillins and their metabolites in body fluids by high-performance liquid chromatography. Author: Thijssen HH. Journal: J Chromatogr; 1980 Sep 12; 183(3):339-45. PubMed ID: 7419651. Abstract: A high-performance liquid chromatographic assay method to quantitate the isoxazolyl penicillins, their active metabolites, and their penicilloic acids in serum or urine is described. Separation and analysis is performed using reversed-phase chromatography. Urine samples, after the appropriate dilution, can be assayed directly. Serum samples (0.1 ml) are either extracted with methylene chloride or treated with perchloric acid--methanol. Serum levels as low as 0.4 microgram/ml (extraction procedure) can be assayed accurately.[Abstract] [Full Text] [Related] [New Search]