These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Esophagogastrectomy using the auto suture EEA surgical stapling instrument. Author: Dorsey JS, Esses S, Goldberg M, Stone R. Journal: Ann Thorac Surg; 1980 Oct; 30(4):308-12. PubMed ID: 7425710. Abstract: A stapling instrument, which creates end-to-end inverting anastomoses, is described for esophagogastrostomy. The inverted anastomosis is held together by a double staggered row of stainless-steel wire staples. Experience with 7 consecutive patients who underwent esophagogastrectomy for carcinoma of the distal esophagus or proximal stomach using this device is reported. Postoperative complications included atelectasis in 1 patient, cardiac failure in 1, and pneumonia in 1. A fibrotic stricture developed at the anastomotic site 5 months postoperatively in 1 patient. There were no anastomotic leaks. The stapled anastomosis takes 2 to 3 minutes to perform and seems to be at least comparable to handsewn anastomoses.[Abstract] [Full Text] [Related] [New Search]