These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Gas-chromatographic assay for thiopental in plasma, with use of a nitrogen-specific detector.
    Author: Jung D, Mayersohn M, Perrier D.
    Journal: Clin Chem; 1981 Jan; 27(1):113-5. PubMed ID: 7449092.
    Abstract:
    An accurate, sensitive, and specific gas-liquid-chromatographic procedure is described for determining concentrations of thiopental in human plasma. After a double extraction of 0.2 or 1.0 mL of plasma containing phenobarbital as an internal standard, thiopental and the internal standard are derivatized in a polar non-aqueous solvent system with iodomethane. The reaction mixture is then evaporated, the residue reconstituted with ethyl acetate, and 20 microL injected into a 3% OV-17 column of a gas chromatograph equipped with a nitrogen-phosphorus detector. Linearity and reproducibility over the concentration range 25 microgram/L to 10 mg/L in plasma are excellent. The sensitivity and wide range of linearity exhibited by this method permit thorough characterization of the disposition of thiopental after the usual induction doses of 3-4 mg/kg of body weight.
    [Abstract] [Full Text] [Related] [New Search]