  • Title: Aqueous shunts: single-plate Molteno vs ACTSEB.
    Author: Kim DM, Lim KH.
    Journal: Acta Ophthalmol Scand; 1995 Jun; 73(3):277-80. PubMed ID: 7493245.
    Abstract:
    A retrospective study was done to compare the results of the single-plate Molteno implant surgery with those of the anterior chamber tube shunt to an encircling band procedure in eyes with refractory glaucoma. Both Molteno implant and anterior chamber tube shunt to an encircling band are made of silicone. There were 19 eyes in the Molteno group, 17 eyes in the anterior chamber tube shunt to an encircling band group, with at least 6 months of follow-up. Preoperative intraocular pressure in the Molteno group and anterior chamber tube shunt to an encircling band group was 47.5 +/- 11.4 and 46.5 +/- 10.3 mmHg, respectively. Intraocular pressure at 6 months postoperatively was 20.4 +/- 15.1 and 15.5 +/- 10.4 mmHg, respectively. The difference in pressure reduction between the two groups was not significant statistically. Serious complication rate for 6 months was 11% and 47%, respectively.