These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Comparison of 5% human albumin and 6% 200/0.5 HES as exclusive colloid components in large surgical interventions].
    Author: Vogt N, Bothner U, Georgieff M.
    Journal: Anasthesiol Intensivmed Notfallmed Schmerzther; 1994 May; 29(3):150-6. PubMed ID: 7519062.
    Abstract:
    OBJECTIVE: It was the purpose of the following study to compare effects of 6% hydroxyethyl starch 200/0.5 (HES) and albumin 5% (HA5) on haemostasis, haemodynamics, oncotic function and plasmatic homoeostasis. METHODS: In 2 randomised groups of 20 patients each undergoing large surgery (criteria of exclusion: anaemia, renal, liver, and coagulation disorders, ASA classification > III) we treated up to 1000 ml with colloid solution, from 1000 ml up to 5000 ml with packed red blood cells (PRBC) and colloid solution (1:1) and above 5000 ml with PRBC and fresh frozen plasma (1:1). Group HES received HES and group HA5 albumin as exclusive colloid component and both continuously lactated Ringers' at a rate of 500 ml/h. We measured the parameters before operation, after each 1000 ml colloid up to 3000 ml application and at the end of operation and we registered total blood output/intake. RESULTS: We found comparable amounts of blood loss and blood intake (mean total amount of colloid solution: HES 2044 +/- 579 ml; HA5 2547 +/- 980 ml). We didn't find any differences in haemodynamics nor in haematocrit, platelets or global coagulation parameters which only showed dilutional influences. Differences existed in total serum protein (HES 32.8 +/- 6.5 gr/l; HA5 54 +/- 5.5 gr/l at OP's end); however COP was maintained in both groups during the whole study period at normal ranges. Plasmatic haemostasis showed to a large extent corresponding values. Remarkable was the development of a metabolic acidosis in the HA5 group. CONCLUSION: Regarding total blood output/intake, haemodynamic functions, haematological parameters, coagulation, oncotic function, and plasmatic homoeostasis, HES is a safe colloid if contra-indications are taken into account, capable of replacing albumin 5% entirely as a colloid component of treatment of even large blood losses intraoperatively above the recommended dose of 20 ml/kg BW/d.
    [Abstract] [Full Text] [Related] [New Search]