    Abstract:
    Among the methods for determining anaerobic threshold (AT), the heart rate (HR) method seems to be the simplest. On the other hand, many conflicting results from comparing this method with others have been presented over the last 10 years. Therefore, the aim of this study was to compare the heart rate threshold (HRT) with the lactate turn point (LTP)-"second" break point of dependence of lactate (LA) to power output, ventilatory threshold (VT) and threshold determined by electromyography (EMGAT), all determined by the same exercise test and evaluated by the same computer algorithm. A group of 24 female students [mean age 20.5 (SD 1.6) years, maximal oxygen consumption 48.8 (SD 4.7) ml.kg-1.min-1] performed an incremental exercise test on a cycle ergometer (modified Conconi test) starting with an initial power output (PO) of 40 W with intensity increments of 10 W.min-1 until the subjects were exhausted. The HRT, LTP and EMGAT determination was done by computer-aided break-point regression analysis from dependence of functional measures on PO. The same computer algorithm was used for VT determination from the relationship between ventilation (V) and oxygen uptake (VO2) or carbon dioxide output (VCO2).(ABSTRACT TRUNCATED AT 250 WORDS)