These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Topographical evaluation of skin perfusion patterns in peripheral arterial occlusive disease by means of computer-assisted fluorescein perfusography.
    Author: Scheffler A, Rieger H.
    Journal: Eur J Vasc Endovasc Surg; 1995 Jul; 10(1):60-8. PubMed ID: 7633971.
    Abstract:
    OBJECTIVE: To evaluate the clinical impact of computer-assisted fluorescein perfusography in peripheral arterial occlusive disease (PAOD). DESIGN: Foot and calf skin perfusion was visualised by intravenous fluorescein injection. Fluorescein influx was recorded photographically and converted into functional images of fluorescein appearance times (AT) by means of digital film processing. SETTING: Vascular Laboratory of Clinic for Vascular Disease. MATERIALS: 249 patients with PAOD. Among 481 limbs studied, 83 legs presented with patent arteries, 70 with asymptomatic obstructions (Stage I), 170 with claudication (Stage II) and 158 with rest pain and skin lesions (Stage III/IV). CHIEF OUTCOME MEASURES: Forefoot and calf mean ATs and standard deviations (SD) served as arbitrary measures of regional skin perfusion rates and their homogeneity, respectively. MAIN RESULTS: In the control legs, a homogeneous and fast fluorescence appearance was observed (medians at the foot: AT33.4 s, SD 3.6). In stage II disease, AT (39.9 s, SD 5.6) were slightly impaired as compared to limbs with patent arteries or stage I disease (p < 0.01). Ninety-seven out of the 158 legs in stage III/IV could be managed by conservative therapy. According to fluorescein-perfusography, they did not differ from stage II disease (AT 38.8 s, SD 6.1). Sixty-one limbs were clinically affected by critical ischaemia. They exhibited a markedly delayed and heterogenous fluorescein influx at the foot (AT 77.3 s, SD 26.5, p < 0.01 vs all other groups). Non-fluorescent areas occurred in 53% compared to only 1% of limbs with and without critical ischaemia, respectively. Retrospectively, predictive values of fluorescein perfusography in identifying a critical limb ischaemia (accuracy 93%) were superior to the ankle systolic arterial pressure determination (accuracy 80%). CONCLUSIONS: Fluorescein perfusography seems to be of diagnostic and prognostic use in PAOD in stage III/IV where inflammatory and ischaemic patterns of dye appearance can be distinguished.
    [Abstract] [Full Text] [Related] [New Search]