These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Excision or Silastic replacement for comminuted radial head fractures. A long-term follow-up. Author: Stoffelen DV, Holdsworth BJ. Journal: Acta Orthop Belg; 1994; 60(4):402-7. PubMed ID: 7847090. Abstract: This report comprises a follow-up of 39 patients after simple excision and 16 patients after Silastic replacement of the radial head for displaced comminuted fractures. Prostheses were used when similar fractures were associated with an unstable elbow. The excision group was followed up for 6.1 years on average, and the replacement group for 5.7 years. The objective result after simple excision was good in 55% of cases, fair in 26% and poor in 19%. The results in the replacement group were only 13% good, 38% fair, 37% poor and in 12% the prostheses had to be removed.[Abstract] [Full Text] [Related] [New Search]