These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Is there still a need for Tc-99m DMSA renal imaging?
    Author: Bair HJ, Becker W, Schott G, Kühn RH, Wolf F.
    Journal: Clin Nucl Med; 1995 Jan; 20(1):18-21. PubMed ID: 7895429.
    Abstract:
    Scintigraphy with Tc-99m MAG3 is, to date, the most commonly used technique for evaluating separate renal function (SRF). In this study, the performance of this technique is compared to Tc-99m DMSA. A total of 37 patients with various kidney disorders (12 children and 25 adults) underwent both Tc-99m DMSA and Tc-99m MAG 3 scintigraphy. In children and adults of normal weight the correlation coefficient between the two methods was 0.99 (P < 0.001), whereas in individuals who were more than 10% overweight according to Broca, or who had abnormal anatomical positions of the kidneys, the correlation coefficient was 0.82 (P < 0.05). Scintigraphy with Tc-99m DMSA was more accurate in renal parenchyma lesions. These results indicate that Tc-99m DMSA scintigraphy is preferable for the evaluation of SRF in patients who are more than 10% overweight, or have abnormal positions of the kidneys.
    [Abstract] [Full Text] [Related] [New Search]