These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Pseudoelevation of carboxyhemoglobin levels in firefighters.
    Author: Kales SN, Pentiuc F, Christiani DC.
    Journal: J Occup Med; 1994 Jul; 36(7):752-6. PubMed ID: 7931741.
    Abstract:
    Carbon monoxide is a common and potentially lethal exposure documented by an elevated carboxyhemoglobin (COHb) level. We conducted an investigation of unexpectedly high carboxyhemoglobin levels in a group of firefighters. Twelve of 34 (35%) nonsmokers tested had levels greater than 4% COHb and 9 of 34 (26%) had levels of 10% or higher. Quadruplicate blood samples from hospital staff and firefighters were sent in duplicate to the original laboratory, which used manual spectrophotometry, and to a second reference facility using a cooximeter. Cooximeter results were lower and also more reproducible. By cooximetry, all 24 nonsmoking firefighters retested had COHb levels less than 3%. Cooximetry is widely available and is the most suitable methodology in clinical situations. Spurious results despite the use of a large reference laboratory argue for the standardization of analytic methods for COHb among laboratories.
    [Abstract] [Full Text] [Related] [New Search]