Title: Diagnosis of Streptococcus pneumoniae pneumonia by quantitative enzyme linked immunosorbent assay of C-polysaccharide antigen. Author: Gillespie SH, Smith MD, Dickens A, Raynes JG, McAdam KP. Journal: J Clin Pathol; 1994 Aug; 47(8):749-51. PubMed ID: 7962631. Abstract: AIMS: To evaluate the use of a quantitative enzyme linked immunosorbent assay (ELISA) detecting C-polysaccharide (PnC) antigen in sputum for the diagnosis of Streptococcus pneumoniae infection. METHODS: Specimens of sputum from 60 patients with acute community and hospital acquired pneumonia and infective exacerbations of obstructive airways disease were examined by semiquantitative culture and antigen ELISA. RESULTS: Using a cutoff value of 1 microgram/ml PnC antigen for a positive result, the sensitivity of this assay was 90.3%, specificity 93.1%, predictive value of a positive result was 93.5%, and the predictive value of a negative result 89.6%. CONCLUSIONS: Quantitation of C-polysaccharide antigen in sputum by ELISA distinguishes between carriage of oral bacteria which express PnC-like antigen and infection with S pneumoniae and compares favourably with other diagnostic methods.[Abstract] [Full Text] [Related] [New Search]