These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Reoperations of extracardiac valved conduit for congenital cardiac defects]. Author: Uwabe K, Imai Y, Ishihara K, Hoshino S, Sawatari K, Terada M, Misumi H, Shin'oka T. Journal: Nihon Kyobu Geka Gakkai Zasshi; 1994 Apr; 42(4):557-61. PubMed ID: 8035077. Abstract: Fifteen of 223 patients who have had extracardiac conduit repair at the Heart Institute of Japan from January, 1970, to April, 1991, have required conduits replacement because of conduit obstruction or infection. The main causes of obstruction were degeneration of the prosthetic valve and proliferative pseudo-intima in the conduit. The interval between initial conduit repair and conduit replacement was 2.2 to 18.3 years (mean 10.5 +/- 4.4). The average pressure gradient through the conduit decreased from 74.7 +/- 42.0 mmHg preoperatively to 12.3 +/- 7.1 mmHg postoperatively (p < 0.05). There was no early and late death. We concluded that xeno-pericardial roll conduits were superior to others and that conduit replacement procedure following the extracardiac conduit repair was safe and effective.[Abstract] [Full Text] [Related] [New Search]