These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Correlation of optotypes with the Landolt ring--a fresh look at the comparability of optotypes. Author: Grimm W, Rassow B, Wesemann W, Saur K, Hilz R. Journal: Optom Vis Sci; 1994 Jan; 71(1):6-13. PubMed ID: 8146001. Abstract: The legibility of three selected sets of optotypes: (1) letters; (2) Snellen E; and (3) KOLT test have been compared to the Landolt ring in a study based on the German Standard DIN 58220, Part 2 and the International Standard ISO 8597. The letters were printed in the standard typeface used on German street signs (sans serif Linear-Antiqua, Typeface B). The main results are: 1. A set of letters can be selected in such a way that the differences in legibility displayed between different letters in the set are smaller than the ISO/DIN allowance of 0.05 logarithmic units of the visual angle, although the letters are not constructed according to the traditional 5 by 5 or 5 by 4 construction principles. 2. The eight letters C, D, E, K, N, P, U, Z are proposed for standardized visual acuity tests because of their almost equal legibility. 3. The height of the typeface used for this selected set of letters should be 5% less than the diameter of the Landolt ring in order to achieve the same legibility as the latter. 4. Both shape optotypes (Snellen E and KOLT test) must be approximately 15% smaller than the diameter of the Landolt ring in order to obtain comparable visual acuity scores.[Abstract] [Full Text] [Related] [New Search]