These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Highperformance liquid chromatographic assay for lomefloxacin in plasma and its pharmacokinetics in healthy volunteers].
    Author: Tan L, Xu DK, Diao Y, Yuan YS.
    Journal: Yao Xue Xue Bao; 1993; 28(4):286-9. PubMed ID: 8213172.
    Abstract:
    A sensitive and simplified high performance liquid chromatographic procedure has been developed for quantification of lomefloxacin in human plasma. The recovery of lomefloxacin was 95 to 102%. The relative standard deviation was 2.1 to 7.8%. The calibration curve was linear in the range from 0.125 micrograms/ml to 5.012 micrograms/ml with r = 0.9998. The detection limit of the method is 25 ng/ml. The plasma drug concentration-time course after medication conformed to a 1-compartment open model with a first order absorption. Mean t1/2 value was 5.5 h.
    [Abstract] [Full Text] [Related] [New Search]