These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Reflectance pulse oximetry measurements from the retinal fundus. Author: de Kock JP, Tarassenko L, Glynn CJ, Hill AR. Journal: IEEE Trans Biomed Eng; 1993 Aug; 40(8):817-23. PubMed ID: 8258448. Abstract: Conventional transmission pulse oximetry is a noninvasive technique for the continuous monitoring of arterial oxygen saturation (SaO2) from peripheral vascular beds such as the finger tip or earlobe. In this paper we propose to exploit the unique transparency of the ocular media to make reflectance pulse oximetry measurements on the retinal fundus. This technique potentially offers significant advantages over conventional pulse oximetry, primarily the ability to monitor cerebral, as opposed to peripheral, oxygen saturation. We have developed an in vitro system to stimulate the retinal circulation and ocular optics. This system consists of a flexible cuvette located in a model eye and an extracorporeal blood circuit to stimulate arterial blood flow. The system was used to investigate the relationship between SaO2 and the R/IR ratio in reflectance pulse oximetry. To enable in vivo measurements to be made, we also modified a standard haptic contact lens to hold the pulse oximeter probe in front of the pupil. In a preliminary study, the lens was fitted to an awake volunteer and cardiac-synchronous signals were detected by the retinal pulse oximeter.[Abstract] [Full Text] [Related] [New Search]