These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Mid-frequency hearing loss in rats following inhalation exposure to trichloroethylene: evidence from reflex modification audiometry. Author: Crofton KM, Zhao X. Journal: Neurotoxicol Teratol; 1993; 15(6):413-23. PubMed ID: 8302243. Abstract: The present experiments were undertaken to characterize the hearing loss associated with 1,1,2-trichloroethylene (TCE) exposure. Adult male Long-Evans (LE) rats were exposed to TCE via inhalation (whole body) for 6 h/day for 5 days. The concentration-effect function (0-4000 ppm) was determined 3 weeks post-exposure. Animals were tested for auditory thresholds to 4, 8, 16, 24, 32, and 40-kHz tones using reflex modification audiometry. In a separate experiment, the time course of effects was determined by monitoring 16-kHz thresholds prior to, 1 h following each of the 5 exposure days, and 5 days, 1, 2, 4, 8, and 12 weeks post-exposure. At 14 weeks, these same animals were tested for thresholds to 0.5, 1, 2, 4, 8, 16, 24, 32, and 40-kHz tones. Results indicate elevated thresholds (hearing loss) for the 4000 ppm group at 8 and 16 kHz of approximately 18 and 30 dB, respectively. Time-course data demonstrated a rapid onset, a 20-dB loss at 16 kHz after the fifth exposure day, and a 40-dB loss by 2 weeks that persisted up to 14 weeks post-exposure. These data demonstrate an atypical and persistent, mid-frequency hearing loss in rats following inhalation exposure to TCE.[Abstract] [Full Text] [Related] [New Search]