These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Spatio-temporal interactions in anisometropic and strabismic amblyopia.
    Author: Levi DM, Harwerth RS.
    Journal: Invest Ophthalmol Vis Sci; 1977 Jan; 16(1):90-5. PubMed ID: 832970.
    Abstract:
    Contrast sensitivity functions for sinusoidal gratings of different spatial frequencies and stimulus durations have been determined for both eyes of amblyopic subjects. For both long and short stimulus durations, the entire contrast sensitivity function of the amblyopic eyes is lower than that of the nonamblyopic eyes. When the gratings were flickered at 10 Hz, the sensitivity for pattern and flicker detection were similar for both eyes at low spatial frequencies. Possible neural mechanisms for the differences in contrast sensitivity are considered with respect to recent psychophysical and electrophysiological evidence for channels with different spatio-temporal properties in the mammalian visual system.